| Home | About Us | Portfolio | Enquiry | Contact Us  
 

M-ES Adhesive

Performance

Meiwang super construction adhesive (also called hardener) is characteristic of quick solidification at room temperature (25¢J),good durability and aging resistance. Meiwang adhesive can be widely used to bond and anchor metal threaded studs into base materials (e.g.concrete, rock, stone, clay brick) as well as other building units.

Components: A is cement, B is hardener.

Applications: Reinforce concrete, fix foundation of machinery and bond stone materials with epoxy adhesive

Packing specifications: 2Kg, 8Kg, 20Kg

Formula calculating the amount of cement:
Amount of cement per drill hole(g)=(net cross section of drill hole cm2 - cross section of threaded stud's rod cm2) ¡Ñ depth of drill hole(cm) ¡Ñ density of cement¡Ñ 1.15

Usage

  1. Drill:drill hole with a percussion drill to required and depth in design
  2. Clean:blow off dust from hole with compressed air.
  3. Mix:mix components A and B at ration of A/B=100/3
  4. Fill:fill mixture into hole while discharge air from hole
  5. Harden:Insert metal anchor until it contacts the bottom of the hole, remove any excess mixture from the mouth of hole and make it smooth.
  6. Increase amount of component B in low temperature while decrease B in high temperature, so as to adapt to the actual construction season.

Notes:

  1. Store in a cool ventilated warehouse, and keep from light, heat and open flane.
  2. Mixture shall be used within 20 minutes after mixing. Do not try to apply when mixture hardens.
  3. If there is precipitation during storage, the whole cement in the can should be fully mixed before it applies. Fail to do that, mixture will be present out of proportion and fail to meet requirements.

Shelf Life: One year in an unopened container in the cool place.


Technical parameters

Threaded steel
Diameter(mm)
10 12 14 16 18 20 22 25 28 30
Drill hole
Diameter(mm)
14 16 18 22 25 28 30 32 37 40
Depth hole
Threaded steel(mm)
120 140 180 220 260 300 350 500 550 600
Average pulling
Resistance(kN)
26 37 51 67 85 105 127 164 206 220
Average shearing
Resistance(kN)
18 26 32 47 56 74 88 105 140 168
 
  Copyright © 2006 Shanghai MeiWang Hardware Co., Ltd. All Rights Reserved.